QST-2002
a Cost Effective Solution for Production Testing of HSA
Integrating
HGAs, HSAs, and HDAs with the QST-2002
Top
The following is a list of requirements to integrate an HGA with the
QST-2002 system:
- Flex cable (FOS) drawings, with pad pinout configuration (Up and Down)
- HGA Drawings (Up and Down)
- Sample HGAs (Up and Down)
The following is a list of requirements to integrate an HSA with the QST-2002
system:
- Preamp Chip specifications
- Sample HSAs, including shipping comb
- HSA flex circuit mechanical layout diagram
- HSA flex circuit schematic
- HSA drawings (top and side views) of assembled HSA (with pivot bearing, if
installed during test)
- HSA drawings of pivot hard stop reference surface
- Detailed dimensions of HSA mounting surface or pivot bearing (including
bore size and tolerances)
- 3-D model of assembled HSA importable to ACAD 14 (recommended, but not
required)
- X/Y distance from Pivot Point to Head Gap
- Sample(s) of flex connector used on drive PCB (or detailed specifications
and drawings)
- Direction of rotation of Spindle
- Drawings of shipping comb
The following is a list of requirements to integrate an HDA with the QST-2002
system (note that many of these items are duplicated from the HSA integration
requirements):
- Preamp Chip specifications
- Sample HDAs
- HSA flex circuit mechanical layout diagram
- HSA flex circuit schematic
- HDA drawings, showing flex circuit connector location and installation
height, and HSA park position
- Sample(s) of flex connector used on drive PCB (or detailed specifications
and drawings)
- Direction of rotation of Spindle
|