Version 1.2.1 (Feb 3 2012) - Fixed: Power Monitor error was not logged anywhere Version 1.2.0 (Dec 9 2011) - Fixed: Failcheck min max stopped working in previous version. - Fixed: Failcheck % did not work - Fixed: On the first go around stress was applied with the wrong parameters (different from the ones set in HGA Lifecycle test) - Fixed: If not all 12 heads were enabled then TestOneResult function showed subscript out of range error. Version 1.1.8 (Dec 8 2011) - Added: Power monitor function to check if power got disconnected from 2xBar. Version 1.1.7 (Mar 21 2011) - Fixed: Data shift when running 12x_Constant stress for the first time. Version 1.1.6 (Mar 21 2011) - Fixed: If user turned on fail-on parameters in the HGA Lifecycle test, and ran the test at least once, then saved changes to the setup file, then the setup file became corrupted. Version 1.1.5 (Jan 21 2011) - Fixed: If Number of plots saved when running HGA_Lifecycle test exceeded 256, older plots were overwritten. Version 1.1.4 (July 16 2009) - Fixed: If 12x_constant or 12x_pulsing stress did not run at least once, but was used in the seqeunce, then in the middle of the HGA lifecycle sequence the data columns could shift. Version 1.1.3 (June 8 2009) - Added: Magnetic Field parameter to 12x_constant and 12x_pulsing bias stresses. Version 1.1.2 (Nov 03 2008) - Fixed: Write Stress in 12xConstant did not work. Introduced with 5/22/2008 in Quasi97 release 4.6.32. This release requires Quasi97 4.5.56 - Fixed: If temperature was set too low then an error message appeared, and the test stopped. In this release, the test will try to settle on minimum temperature first, then will turn the heater on. Version 1.1.1 (Nov 03 2008) - Fixed: Optimized the ETA calculation (speed). Further improvements to accuracy are planned. - Fixed: Fixed division by zero errors in 12x_constant - Changed: no more temperature polling. - Fixed: Multiple result rows per head in 12x_Pretest if the log individual option was turned on. Version 1.0.11 (May 30 2008) - Fixed: Intead of overwriting the test parameters, those were added after every test. So each new iteration would have more columns than the previous one in the log file. This is if selective logging was disabled. - Fixed: If selective logging was enabled, the test would run until the number of parameters got bigger than 32000. Then the test would generate "CreateStatArray: Subsript out of range" error. Version 1.0.10 (May 5 2008) - Fixed: Sometimes did not run the last head during HGA lifecycle test. This is when the head before last was disabled. - Added: Different data logging arrangement - Fixed: Object or with variable not set, if using 12x_Pretest Version 1.0.9 (May 5 2008) - Fixed: Parameters were not saved to the setup file in 12xConstant, 12xPulsingBias, HGA Lifecycle test, 12x_Pretest. - Fixed: 12x_Constant did not save aux parameters, after reopening the form the parameters were reset. - Added: Button to apply setting to all channels in 12x_Constant and 12x_Pulsingbias - Changed: the name of the parameter in 12x_Constant from Interval(s) to Stress Interval(s) - Added: When "Test" tab is selected in HGA lifecycle test, the sequence tree is disabled now. - Fixed: HGA Lifecycle software shuts down abnormally when editing parameters or opening/closing 12x_* test forms. Version 1.0.8 (Mar 14 2008) - Fixed: Alex Percent changed to Aux percent on the 12xConstant menu. - Fixed: No current record error message Version 1.0.6 (Feb 26 2008) - Fixed: In 12x_constant current board was writing - no matter if it was enabled or not. Version 1.0.5 (Feb 18 2008) - Added: Heater Off Functionality Version 1.0.4 (Feb 18 2008) - Added: Dual Channel testing. - Added: Adaptive parameters handling. Version 1.0.3 (Jan 10 2008) - Fixed: Gen 3 Calibration - Fixed: resistance delta and other tests slower on Board 2-6 Version 1.0.1 (Jan 09 2008) - Fixed: The bias current was not restored after running constant stress in engineering mode. Version 1.0.0 (Jan 09 2008) - Initial Release